User ManualPlease read before using this equipment.

Strany 2 - Table of Contents

84.3.Verifying the Basic OperationYour Sensor Unit comes pre-programmed with a unique ID code so it will only work withyour Display Unit. This synchro

Strany 3 - We l c o me

955.1.You Will Need…It is very important to follow the installation instructions for the PowerCost Monitor™exactly as outlined in this User Guide for

Strany 4 - Your PowerCost Monitor™

105.2. Electromechanical MeterElectromechanical meters have dials on the face and a spinning disk with a black mark.The faster the disk spins, the hig

Strany 5 - 2.2. Care and Maintenance

114. Make sure that the Sensor Arm is properly positioned with the disk on the utility meter.It should be positioned so that the alignment line on the

Strany 6

125.3. Electronic Meter (Optical Port on Face)Electronic meters have digital readouts,as well as an optical port which emits light pulses similarto th

Strany 7 - , YOU CAN FOLLOW

135.3.2. Installing Your Sensor Unit1. Adjust the sensor mounting strap by turning the adjustment screw several turns with a flat head screwdriver unt

Strany 8 - LESS THAN 1.5 inches from

145.4. Electronic Meter (Optical Port on Face – Shims Required)Electronic meters have digital readouts,as well as an optical port which emits light pu

Strany 9 - 4.2. Powering the Sensor Unit

15The supplied rubber shims are required to achieve proper installation.4. Loosen the hose clamp and determine by eye if one or two shims will be requ

Strany 10

5.5. Electronic Meter (Optical Port on Top)Electronic meters have digital readouts,as well as an optical port which emits light pulses similarto the i

Strany 11 - Sensor Unit Installation

4. Push the smaller end of the Sensor Arm upwards through the latch opening.5. Push the Sensor Head behind the strap,and as far down as it will go int

Strany 13

12. Slide the Sensor Unit over the glass dome and align the edges of the Sensor Unit body with the white sidelines on the template.13. Tighten the hos

Strany 14 - Optical Port

5.6. Re-synchronizing your Display and Sensor UnitsNOTE: You normally only need to synchronize your Display and Sensor Units once. If you replacethe b

Strany 15

6Setting Up Your Display Unit20Once the Sensor Unit begins to detect power usage from your utility meter, the DisplayUnit automatically starts showing

Strany 16

6.2. Display Unit Buttons and IconsThe pictures below illustrate all the various icons and values that can be displayed at any giventime on your Displ

Strany 17

22ICON/BUTTON PURPOSEDisk Emulator When spinning, indicates that the Display Unit is receiving a signal from the Sensor Unit. The higher the energy co

Strany 18

ICON/BUTTON PURPOSE×Increase: During setup, each press of the button INCREASES the target value on the display by various increments. In some cases, i

Strany 19

246.3. Setting Up for SINGLE (FLAT) RATE BillingIMPORTANT: The instructions that follow assume that your Sensor Unit is transmittingsignals normally t

Strany 20

257. Press ×or Ø Set the correct day of the week.Select the correct Day-of-Week segment.8. Press SET Your Day-of-Week segment is stored and the curren

Strany 21

266.4. Setting Up for TIERED RATE BillingIMPORTANT: The instructions that follow assume that your Sensor Unit is transmittingsignals normally to your

Strany 22 - Setting Up Your Display Unit

277. Press ×or Ø Set the correct day of the week.Select the correct Day-of-Week segment.8. Press SET Your Day-of-Week segment is stored and the curren

Strany 23

Thank you for purchasing the PowerCost Monitor™ from Blue Line Innovations.The PowerCost Monitor™ can help you reduce your electricity bill. Our goal

Strany 24

14. Press SET Your Threshold value is set.“2” is displayed under RATE, and the currently stored value for the Rate 2 flashes next to the ¢/kWh segment

Strany 25

296.5. Setting Up for TIME-OF-USE BillingIMPORTANT: The instructions that follow assume that your Sensor Unit is transmittingsignals normally to your

Strany 26

307. Press ×or Ø Set the correct day of the week.Select the correct Day-of-Week segment.8. Press SET Your Day-of-Week segment is stored and the curren

Strany 27

3114. Press SET Your ON-PEAK RATE is stored. The currently stored ON-PEAK start time value appears and the HOURS digits of the clock flash.15. Press×o

Strany 28

3220. Press SET Your OFF-PEAK Start Time HOURS is stored.The MINUTES digits are flashing.21. Press ×or Ø Set your OFF-PEAK RATE Start Time- MINUTES.Ea

Strany 29

3377.1.Your Display UnitWhen the Sensor Unit begins to detect power usage from your utility meter and theDisplay Unit receives the Sensor Unit signals

Strany 30

347.1.2. Total Consumption RowAfter a few minutes, the value in the third row (Totals Row),starts increasing and provides thetotal cost of electricity

Strany 31

7.2. Dollar & Cents Display ModeThe first screen you will see once the PowerCost Monitor™ starts functioning is similar to the one below.Pressing

Strany 32

7.3. Kilowatt and Kilowatt-Hours ModeTo enter the Kilowatt and Kilowatt-Hours screen, press and release the MODE button located onthe back of the Disp

Strany 33

7.4. Temperature DisplayThe PowerCost Monitor™ displays the temperature reading at the location of the Sensor Unit.The temperature can be displayed in

Strany 34

22Your PowerCost Monitor™ gives you the advantage of real-time feedback. Tests have proven that households where real-time feedback is put to good use

Strany 35 - Display Unit Functions

387.5. Loss of Signal DisplayIn the event that your Display Unit loses the signal from the Sensor Unit you will see a screensimilar to one of the two

Strany 36

7.6. Resetting the Total ValuesPress-and-hold the CLEAR button located on the front of the Display Unit until you hear a beepto reset the Total values

Strany 37

&&&8TroubleshootingIn the event that you are experiencing difficulty installing or using your PowerCost Monitor™system, please refer to th

Strany 38

When I try to synchronize my Display and Sensor Units, the Display Unit keeps showing “id” on the screen.This indicates that the Display Unit is in ID

Strany 39 - 7.4. Temperature Display

The temperature shown on the Display Unit does not match weather reports or appears to be incorrect.The temperature shown on the Display Unit is the a

Strany 40 - 7.5. Loss of Signal Display

LIMITED ONE YEAR WARRANTYBlue Line Innovations warrants this product to be free from defects in materials and workmanship for a period of one year fro

Strany 41 - 7.7. Display Backlight

Specifications2 AA Alkaline Batteries (LR6 or equivalent)2 AA Alkaline Batteries (LR6 or equivalent)Display UnitSensor UnitPower433.92MHzApproximately

Strany 42 - Troubleshooting

FCC Class B Part 15This device complies with part 15 of the FCC Rules.Operation is subject to the followingtwo conditions:1. This device may not cause

Strany 43

187 Kenmount RoadSt. John’s NL CanadaA1B 3P9www.bluelineinnovations.comToll Free: (866) 607-2583P/N: BLI-00193 Rev 2© BlueLine Innovations Inc.PowerCo

Strany 44

32.1. Safety InstructionsThis device does not interfere with your utility meter readings in any way.After the PowerCost Monitor™ is installed, utility

Strany 45 - Warranty

34Your utility meter is most probably located outside your house and it looks like one of the pictures on the following two pages.Your PowerCost Monit

Strany 46 - Specifications

5Electronic MeterMeasure the distancebetween the FRONT opticalport and the outer rim of thedome. It should be NO LESSTHAN1.5 inches (37 mm).Use Quick

Strany 47 - FCC Information

Your meter looks like this… … with the Sensor Unit mounted6Electronic Meterwith TOP optical port.You will need the clearalignment template.See section

Strany 48 - Toll Free: (866) 607-2583

74Unpacking and Verifying Basic OperationVerify that your box contains all the following components:• Display Unit•Sensor Unit• Rubber Shims (2)• Clea